Digital Type Digital Panoramic X-ray equipment Cypher / CypherE

Evolution Function+Design

Everywhere in the advanced dental clinics show kind consideration for the agreeable atmosphere for patient. For example, gentle appearance and interior design of the clinic, cure space with full protection of privacy, creation of relaxing atmosphere by aromatherapy, …
The same consideration is also requested to X-ray unit which is essential for dental diagnostic.
Cypher is a solution of the new generation digital panoramic X-ray unit attaching the importance to the provision of agreeable atmosphere for both patient and clinic.

Function

Cypher has the basic performances to provide clear image and excellent operability as well as “the function gentle to human and environment”. For example, when you align the positioning beams to a patient, Cypher moves to the position automatically with the beams. Cypher is capable of smooth exposure without compelling a patient to take unnatural posture. After exposure, X-ray image of the patient is displayed on a PC monitor at the side of the chair in real time. Further, the versatile image processing function of the software(ADR PLUS) provides the diagnosis information necessary for dental care, supports the clinic to provide advanced dental care and correct orientation of treatment, and supports the clinic to enhance the quality of informed consent.

Design

The first the eye-catching of a patient who enters to the X-ray room is X-ray unit.
Dressed in pearly white appearance, Cypher creates luxury, fashionable and clean atmosphere for patient. Also its round form realizes to give mild impression.
Gentleness and comfortableness are expressed in the design of Cypher.

Technical

Technical Specification
Generic nameDigital panoramic X-ray diagnostic unit
Product nameDigital Panoramic X-ray equipment
TypeCypher| Cypher E
Source voltage100/110/120/200/220/230/240V 50/60Hz, 1Φ
Power requirement1.5 kVA
High voltage
generator
Inverter type
Tube voltage60 to 80 kV (1 kV step)
Tube current2 to 8 mA (1 mA step)
ExposureManual exposure
X-ray tubeD-052SB
Focal spot0.5 mm
Total filtration2.5 mm Al (min)
Exposure modePanoramic : Adult/Child
TMJ 4 section views (lateral view)
Exposure timePanoramic : 10 sec
TMJ 4 section views (lateral view) : 2.5 sec (×4)
Image
magnification
Panoramic : 1.2 to 1.3
TMJ 4 section views (lateral view) : 1.2
Image sensorCCD sensor| C-MOS sensor
Positioning beam3 beams (median, ear-eye plane, anterior teeth)
DimensionsW : 906 × D : 1,126 × H : 2,200 (mm)
WeightApprox. 165 kg
Operating Environment
Temperature5 to 35 °C
Humidity30 to 85 %
Atmospheric
pressure
700 to 1,060 hPa